Video Surveillance Systems Ltd.

1540 Rue des Orioles,
Sainte-Catherine,
QC J5C 1R7, Canada
E-Mail Address: office@distance-surveillance.ca
Telephone: (514) 623-6038
distance-surveillance.ca

Video Surveillance Systems Ltd.

MIRCOM MP-320R PRE-ACTION/DELUGE/AGENT RELEASING CONTROL UNIT

https://distance-surveillance.ca/mircom-mp-320r-pre-action-deluge-agent-releasing-control-unit



MIRCOM MP-320R PRE-ACTION/DELUGE/AGENT RELEASING CONTROL UNIT
Product QR Code
  • SKU Mircom-MP-320R
  • Brand: Mircom
  • Product Code: 895-01
  • Availability: In Stock
  • $20.93

Reviews (0)

Description

Mircom’s FR-320 is a dual releasing control unit that is field configurable for use on Deluge Sprinkler Systems, Pre-action Sprinkler Systems and Agent Release Systems.

  •  Listed to UL 864, 9th edition
  •  Field configurable to operate with a Deluge Sprinkler System, a Pre-action Sprinkler System and an Agent Release System
  •  Six Class B (Style B) Input Circuits
  •  Input Circuits One to Four can be configured as Non-Verified Alarm, Non Latching Supervisory, Latching Supervisory or Agent Release/Water Flow depending on the Mode of Operation selected
  •  Input Circuits Five & Six can be configured as Manual Release Input, Abort Input or Abort/Manual Release Combination Input depending on the Mode of Operation selected
  •  Input Circuits can be converted to Class “A” (Style “D”) using the ICAC-306 Converter Module
  •  Four Class “B” (Style “Y”) Output Circuits which can be configured for Silenceable Signal, Non-Silenceable Signal, Silenceable Strobe, Non-Silenceable Strobe or Releasing Circuit (Circuits 3 & 4 Only)
  •  Output Circuits can be converted to Class “A” (Style “Z”) using the OCAC-304 Converter Module
  •  5 Amp Power Supply
  •  4-wire smoke power 22.3 VDC @ 300ma max. Supervised Aux Power 22.3 VDC @ 500ma max.
  •  Aux Power (Unregulated) 24 VDC @ 1.7 Amp max.
  •  Relay contacts for Common Alarm (Non Disconnectable), Auxiliary Alarm (Disconnectable), Common Supervisory (can be converted to common alarm if no Supervisory input) and Common Trouble
  •  Cross Zone option
  •  Counting Zones option
  •  Output signals can be configured for Steady (fixed) or Escalating (tone changes as input operation changes)
  •  Release Timer 0 to 60 Seconds (5 second increments)
  •  Manual Release Delay 0 to 30 Seconds (5 second increments)
  •  Soak Timer 0 to 15 Minutes (21 Intervals)
  •  Abort Release Timer (Standard UL Type Delay, IRL Type Delay, NYC Type Delay, Local Jurisdiction Delay)
  •  Special Releasing Power Supply and Release Activation Considerations preventing false dumps
  •  Configurable to perform two hazard areas
  •  Simple panel programming through 14 Pre-Configured Modes of Operations